Applications
Measurement of differential pressure or of two different
pressures applied in refrigeration plants or compressors
Simultaneous measurement of the vapour pressure and the
resulting vapour temperature
For gaseous and liquid aggressive media that are not highly
viscous or crystallising, also in aggressive ambience
Special Features
Differetial pressure with moving dial
Design optionally with duplex scale
With liquid-filled case for damping in applications with
high dynamic pressure pulsations or vibrations and for avoiding condensation
water Model 733.18
Combined pressure and temperature scales as duplex, triples
or quadruplex scales for all common refrigerants
Description
Design
Two independent measuring systems, parallel entries in line
Nominal size in mm
80, 100
Accuracy class
1.6
Scale ranges
0 ... 2.5 to 0 ... 60 bar -1 ... 0 ... +25 bar
-1 ... 0 ... +12 bar -1 ... 0 ... +30 bar
-1 ... 0 ... +15 bar -1 ... 0 ... +35 bar
-1 ... 0 ... +16 bar -1 ... 0 ... +40 bar
Other scale ranges on request
In order to ensure a good readability, the differential
pressure should be no less than 1/6 of the full scale value.
When ordering state both pressures:
a) maximum total pressure applied, b) differential pressure
Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
Permissible temperature
Ambient: 0 ... +60 °C
Medium: +100 °C maximum
Temperature effect
When the temperature of the measuring system deviates from
the reference temperature (+20 °C):
max. ±0.4 %/10 K of full scale value